【车载以太网案例】全新100/1000BASE-T1 IOP测试解决方案
2021年5月份,北汇信息基于对IOP测试的理解和经验积累,根据OPEN Alliance 1000BASE-T1(Draft)物理层测试规范,采用了基于Vector CANoe、VN5650、VT System和Technica Golden Device组合式的方案,实现了1000BASE-T1 IOP测试。如今,北汇基于Technica公司升级版的Golden Device,推出“一站式”100&1000BASE-T1 IOP测试解决方案。
1
测试方案简介
Link-up Time
Link-up Time - Trigger:Power on Link Partner 被测控制器上电且唤醒,使用Vector CANoe CAPL编程触发Golden Device的Link-up Time - Trigger:Power on Link Partner测试程序,Golden Device自动记录每次的Link时间并回传给Vector CANoe软件
►►►
Link-up Time - Trigger:Power on DUT
使用Vector CANoe CAPL编程触发Golden Device的Link-up Time - Trigger:Power on DUT测试程序,Golden Device自动记录每次的Link时间并回传给Vector CANoe软件。
Link-up Time - Trigger:Wake-Up DUT
Signal Quality
OABR_SIGNAL_01:Indicated signal quality for channel with decreasing quality
►►►
OABR_SIGNAL_01:Indicated signal
quality for channel with decreasing quality
将Golden Device的Link Partner与被测控制器PHY端口连接,通过CANoe CAPL编程修改噪声模式(100BASE-T1/1000BASE-T1)和噪声等级,以及发送被测控制器测试指令获取DUT的SQI和Link Status。
Cable Diagnostic
OABR_CABLE_01:Cable diagnostics for near and far end short OABR_CABLE_02:Cable diagnostics for near and far end open OABR_CABLE_03:Cable diagnostics for good cable 将Golden Device的故障注入模块串联在Link Partner端口和被测控制器PHY端口之间,通过CANoe CAPL编程实现短路/开路故障自动注入功能,以及发送被测控制器指令获取DUT的Cable Status
2
测试案例简介
测试工程
测试报告
3
总结
测试方案对比
TC14(10BASE-T1S)
典型测试条目如下:
proper communication of transmission cycles under different stress conditions PLCA robustness for stressing of clock synchronization and PLCA state machine PLCA diagnostic Signal Quality Harness Defect Detection Topology Discovery Wake-up Sleep
TC15(MultiGBASE-T1)
典型测试条目如下:
Reliability of indicated link status directly after link-up / PHY reset Reliability of indicated link status when connected to link partner with same MASTER/SLAVE configuration Revoke of link status after link-down Link-up after PHY-reset Link-up after reset of link partner Indicated signal quality for channel with decreasing quality Indicated signal quality for channel with increasing quality Cable diagnostics for error-free channel Cable diagnostics for near and far end open Cable diagnostics for near and far end short
往