博文速递:Can hold check be frequency dependant?
作者:VLSI UNIVERSE
Can hold check be frequency dependant?
We often encounter people argue that hold check is frequency independent. However, it is only partially true. This condition is true only for zero-cycle hold checks. By zero cycle hold checks, we mean that the hold check is performed on the same edge at which it is launched. This is true in case of timing paths between same polarity registers; e.g. between positive edge-triggered flops. Figure 1 below shows timing checks for a data-path launched from a positive edge-triggered flip-flop and captured at a positive edge-triggered flip-flop. The hold timing, in this case, is checked at the same edge at which data is launched. Changing the clock frequency will not cause hold check to change.
Figure 1: Setup and hold checks for positive edge-triggered to positive edge-triggered flip-flop
Most of the cases in today’s designs are of this type only. The exceptions to zero cycle hold check are not too many. There are hold checks for previous edge also. However, these are very relaxed as compared to zero cycle hold check. Hence, are not mentioned. Also, hold checks on next edge are impossible to be met considering cross-corner delay variations. So, seldom do we hear that hold check is frequency dependant. Let us talk of different scenarios of frequency dependant hold checks:
1.From positive edge-triggered flip-flop to negative edge-triggered flip-flop and vice-versa: Figure 2 below shows the setup and hold checks for a timing path from positive edge-triggered flip-flop to a negative edge-triggered flip-flop. Change in frequency will change the distance between the two adjacent edges; hence, hold check will change. The equation for hold timing will be given for below case as:
Tdata + Tclk/2 > Tskew + Thold
Tslack = Tclk/2 - Thold - Tskew + Tdata
Thus, clock period comes into picture in calculation of hold timing slack.
Figure 2: Setup and hold checks for timing path from positive edge-triggered flip-flop to negative edge-triggered flip-flop
Similarly, for timing paths launching from negative edge-triggered flip-flop and being captured at positive edge-triggered flip-flop, clock period comes into picture. However, this check is very relaxed most of the times. It is evident from above equation that for hold slack to be negative, the skew between launch and capture clocks should be greater than half clock cycle which is very rare scenario to occur. Even at 2 GHz frequency (Tclk = 500 ps), skew has to be greater than 250 ps which is still very rare.Coming to latches, hold check from a positive level-sensitive latch to negative edge-triggered flip-flop is half cycle. Similarly, hold check from a negative level-sensitive latch to positive edge-triggered flip-flop is half cycle. Hence, hold check in both of these cases is frequency dependant.
Figure 3: Clock gating hold check between data launched from a negative edge-triggered flip-flop and and clock at an OR gate
Similarly, data launched from positive edge-triggered and gating clock on an AND gate form half cycle hold. However, this kind of check is not possible to meet under normal scenarios considering cross-corner variations.
3.Non-default hold checks: Sometimes, due to architectural requirements (e.g. multi-cycle paths for hold), hold check is non-zero cycle even for positive edge-triggered to positive edge-triggered paths as shown in figure 4 below.
Figure 4: Non-default hold check with multi-cycle path of 1 cycle specified
This article is from VLSI UNIVERSE:https://vlsiuniverse.blogspot.com/2015/04/can-hold-be-frequency-dependant.html
If any content of this article infringes, please contact us to remove this article.